|
|
|
| |
|
THCP
2-channel TENS unit
with timer
Two channel
TENS unit. Adjustable pulse width and rate. Modes- burst, normal and
modulation. Treatment times- 15 min., 30 min., and constant. Includes
1 pair of lead wires, 4 pack of electrodes, battery, instructions
and carrying case. One year warranty. |
| Part
# |
Description |
| THCP-TENZ |
THCP
TENS Unit with Timer |
|
|
|
Dynatronics
Digital 2-Channel TENS Unit with Timer
Includes unit,
carrying case, lead wires, electrodes, 9V battery and manual. One
year warranty. Adjustable pulse intensity, rate and width. Three
modes: burst, continuous and modulation. LCD panel shows modes,
pulse rate, pulse width, timer and CH1/CH2. Patient compliance meter
shows the treatment times in hours. Timer: 15, 30, 60 min. and continuous.
|
| Part
# |
Description |
| DYNDGDIGT |
Dynatronics
Digital TENS with timer |
| |
|
Dynatronics
Digital 2-Channel EMS Unit with Timer
Includes
unit, carrying case, lead wires, electrodes, 9-volt battery and
operation manual. One year warranty. Cap and slide cover to protect
accidental changes in settings. Dual, isolated between channels.
Pulse amplitude Adjustable 0-90mA peak into 500 load each channel,
constant current. Pulse Rate 1Hz-160Hz (adjustable), 1Hz/step. Patient
compliance counter shows the treatment times in hours. Timer: 15,
30, 60 minutes and continuous. LCD shows modes, pulse rate/On/Ramp/Off
time, timer, CH1/CH2. Function modes: synchronous, constant, and
alternation. Asymmetrical Bi-phasic square pulse waveform. |
| Part
# |
Description |
| DYNDGEMS |
Dynatronics
Digital EMS with timer |
| |
|
Dynatronics
Digital 2-Channel Interferential Unit with Timer
Includes
unit, carrying case, lead wires, electrodes, battery, 9V DC Adaptor
and operation manual. One year warranty. Cap and slide cover to
protect accidental changes in settings. Dual, isolated between channels.
Pulse intensity: Adjustable 0-70mA peak into 500 ohm load each channel,
constant current. Carrier Frequency: 4000Hz fixed (CH1). Modulating
Frequency: 4004-4160Hz adjustable (CH2). IF Frequency Mode: Constant
Mode: 4-160 bps, adjustable. Auto sweep: 80 -145 bps, 4 - 45 bps,
4 - Set bps. Frequency shift: 1/1 abruptly shift, 6/6 abruptly shift,
6/6 ramped, 10/10 abruptly shift, 10/10 ramped. Sweep time 15 seconds.
Frequency shift percent: Frequency shifts from 30% below set frequency
to 60% above and return to 30% below set. Output configuration:
quad polar (4 electrodes). Symmetrical balanced Sine wave. Interference
pulse freq: 4-160 bps, adjustable 4 bps/step. Pulse duration: 125µs
maximum. Patient compliance meter shows the treatment time in hours.
Patient lock prevents the patient from changing any fixed parameters
set by the physician/practitioner. Timer: 15 or 30 minutes. LCD
shows modes, bps rate, abrupt/ramp, timer and channels. |
| Part
# |
Description |
| DYNDGIFC |
Dynatronics
Digital Interferential Unit with timer |
Copyright
© 2002 Therapy & Health Care Products, Inc.
1598 Motor Inn Drive, Girard, Ohio 44420
Phone: (800) 824-8212 E-mail: info@thcpweb.com
Business
Policies |